    摘要:

    临床分离的淋病奈瑟菌以无菌生理盐水10倍系列稀释,制备成不同浓度的菌悬液,作为PCR质控 发给广东省部分开展淋病PCR检验的实验室,23个回报结果中,假阳经17.6%。10CFU淋球菌检出率15.7%,10^2CFU检出率27.2%,10^3CFU检出率53.9%。总符合率44.8%,结果表明,一些实验室不仅存在假阳性问题,而且阳性检出率也不高,应引起主度重视。

    Abstract:

    Three sets of water samples with Neiseria gonorrhoeae and one without bacteria were prepared as quality control materials of PCR.Several laboratories in Guangdong province were asked to determine the presence or absence of Neiseria gonorrhoeae by application of PCR.Twenty three participating laboratories had returned the results. False positive PCR results were 17 6%, Positive PCR results were reported for 15 7% of the samples with 10 CFU, for 27 2% with 10 2 CFU and for 53 9% with 10 3 CFU,respectively. The results of the study show that the implementation of an effective system for monitoring false positive and false negative is required before the PCR can be used reliably in routine laboratories in the diagnosis of Neseria gonorrhoeae.