    摘要:

    建立了一种安全,简便、敏感涂片查抗酸杆菌方法。痰标本加等体积10%84消毒液和0.5ml的三甲苯,室温下,充分混合154分种,痰液化后,室温静置15分层。用接种环取液相与二甲苯层之间的魄粘末层物质涂片,进行染色或金胺O荧光染色。此法消毒效果可靠,敏感性较直接涂片法高。

    Abstract:

    The direct smear examination for detection of tuberculosis is the most common method in our country. For safety of laboratory workers and improvement the sensitivity of the smear examination, a method was developed in which acid fast bacilli were killed with 10% 84 disinfectant and concentrated by foltation on a layer of xylene before staining by the Ziehl Neelson or auramine O methods. The best results were obtained by auramine O staining after flotation. Staining by Ziehl Neelsen method after flotation gave better results than direct Ziehl Neelsen staining without flotation. It's testified that the method can kill or inactivate Mycobacterium tuberculosis. The flotation method offers advantages for smear preparation in local clinical tuberculosis laboratory.