血清IgG4与IgG比率在IgG4相关性疾病中的诊断价值
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Analysis of the diagnostic value of serum IgG4 to IgG ratio in IgG4-related diseases
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的?探讨血清IgG4含量及IgG4与总IgG的比率在IgG4相关性疾病(IgG4-related diseases,IgG4-RD)中的诊断价值。方法?收集苏州大学附属第二医院体检健康人群(健康人对照组)血清80份,IgG4-RD确诊患者(IgG4-RD组)血清33份,其他自身免疫病组血清150份。用免疫比浊法检测各组血清IgG4和IgG含量,计算IgG4与IgG的比率。绘制血清IgG4、IgG4/IgG比率诊断IgG4-RD的ROC曲线。结果?以血清IgG4≥1.35g/L作为参考值,健康人对照组、其他自身免疫病组和IgG4-RD组IgG4阳性率分别为1.25%、16.67%、100%,IgG4-RD组与健康人对照组阳性率差异有统计学意义(χ2=108.306,P<0.05),其他自身免疫病组与健康人对照组阳性率差异也有统计学意义(χ2=12.368,P<0.05)。与健康人对照组相比,IgG4-RD组血清IgG、IgG4、IgG4/IgG均明显升高,其他自身免疫病组血清IgG、IgG4升高,差异均有统计学意义(P<0.05),而IgG4/IgG无明显升高。以IgG4、IgG4/IgG绘制ROC曲线,血清IgG4为2.49 g/L时,敏感性为95.45%,特异性为93.04%,曲线下面积为0.988 4;血清IgG4/IgG为13.44%时,敏感性为95.45%,特异性为96.09%,曲线下面积为0.994 5。以血清IgG4≥2.49 g/L联合IgG4/IgG≥13.44%作为判断标准,其他自身免疫病组血清IgG4阳性率由16.67%下降至3.33%。结论?IgG4水平以1.35 g/L作为参考值上限在IgG4-RD的诊断中特异性不强。血清IgG4≥2.49 g/L与IgG4/IgG≥13.44%联合应用,在IgG4-RD诊断中具有较高的诊断效能。

    Abstract:

    Abstract: Objective To study the diagnostic value of serum IgG4 content and ratio of IgG4 to total IgG in IgG4 related diseases (IgG4-RD). Methods Taking serum IgG4≥1.35g/L as the upper limit of reference value, the positive rates of IgG4 in the control group, other autoimmune diseases group and IgG4 RD group were 1.25%, 16.67% and 100% respectively. There was significant difference in the positive rate between the IgG4 RD group and the control group (Χ2= 108.306, P<0.05). The positive rate of other autoimmune diseases group was significantly different from that of the control group (Χ2=12.368, P <0.05). Compared with the control group, the serum IgG, IgG4 and IgG4/IgG ratio in IgG4 RD group were significantly increased (P<0.05), while the serum IgG and IgG4 in other autoimmune diseases group were significantly increased (P<0.05), but the IgG4/IgG ratio was not significantly increased (P>0.05). When serum IgG4≥2.49g/L combined with IgG4/IgG≥13.44% was used as the judgment standard, the positive rate of serum IgG4 in other autoimmune diseases decreased from 16.67% to 3.33%, and the diagnostic specificity was significantly improved. Conclusion The upper limit of the reference value of IgG4 level is 1.35g/L, which is not specific in the diagnosis of IgG4-RD. The combined application of serum IgG4≥2.49g/L and IgG4/IgG≥13.44% has high diagnostic efficiency in the diagnosis of IgG4-RD.

    参考文献
    相似文献
    引证文献
引用本文

曹颖,王冰莹,杜鸿,曹伟,杨勇.血清IgG4与IgG比率在IgG4相关性疾病中的诊断价值[J].临床检验杂志,2021,(2):123-125

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2020-09-03
  • 最后修改日期:2021-03-21
  • 录用日期:2021-03-21
  • 在线发布日期: 2021-05-13
  • 出版日期: 2021-02-28
文章二维码
您是第位访问者  苏ICP备13058113号-3
苏公网安备32010202012004号
主管单位:江苏省医学会  出版单位:临床检验杂志
单位地址:江苏省南京市中央路42号  邮编:210008
电话:025-83620683 E-MAIL:lcjyzz@163.com
技术支持:北京勤云科技发展有限公司